1 Installation
port. The freezer can unfortunately not be used with these XE models.
Caution:
The freezer electronic and the adapter board are not connected when they
are shipped to prevent damage during transport. The Atari should always be switched off
to also prevent damage when attaching or detaching the adapter board to/from the Atari
or when attaching or detaching the freezer electronic module to/from the adapter board.
1.1 Verifying the power supply
Owners of Atari XL computer should verify the availability of the 5V power supply on the
PBI before assembling the freezer. Owners of Atari XE computer can skip this step.
First switch the Atari off. Then attach the empty Atari XL adapter board without the
freezer electronic module to the PBI. Now switch the Atari on. If the 5V LED on the
adapter board lights up, then the 5V power supply is available on the PBI and the power
supply wire to the joystick port is not required. Even so, the external power supply wire
should not be cut off, but rolled up and put away because it may be required for use on a
different Atari without the PBI power present. After that, switch the Atari off again and
detach the adapter board from the PBI.
1.2 Assembling the freezer
1.2.1 Protecting from electro-static discharge
You should
electrically ground
yourself before assembling the freezer to discharge electro-
static potentials which may be caused for example by the carpet, shoes, clothing and so
on. These potentials can reach several 1000 volts and might destroy the XILINX chip and
other ICs of the freezer.
Also never touch the multi-pin connectors of the freezer
without being grounded.
This is true in general for all kinds of electronic parts. And
though the Atari is not too sensitive in this regard, it may still get damaged.
You best touch the heating or the protective earthing conductor pin of a power outlet.
Well suited, and very common in the professional area, are ESD (electro-static discharge)
wristbands to ground you permanently.
1.2.2 Connecting the freezer electronic with the adapter board
At the bottom of the module with the freezer electronic there are two multi-pin connectors
with 2x25 pins each. On the adapter board there are two female connectors with 2x25
pins each. The freezer module with the freezer electronic must be plugged into the adapter
board in a way that the front side with the switches points towards the PBI or ECI port of
the Atari.
The module must never be plugged in the other way around because
that may destroy the freezer.
At first the module with the freezer electronic must be positioned over the female connec-
tors in a way that all pins of the multi-pin connectors are located over the corresponding
female connectors.
No pins must overlap.
The best way is to hold the module with the
12