1 Installation
The
TURBO FREEZER
is simply attached to the parallel bus. The parallel bus differs
between Atari XL and XE computers. In Atari XL computers the parallel bus consists of
the Parallel Bus Interface (PBI) which is labeled “Parallel Bus”. In Atari XE computers the
parallel bus consists of the cartridge port and the Enhanced Cartridge Interface (ECI) which
are labeled “Cartridge” and “Expansion”. The power supply of the
TURBO FREEZER
is taken from the parallel bus. In Atari 600 XL and older Atari 800 XL computers the
required power is available directly on the parallel bus. It is no longer available there in
new Atari 800 XL models and therefore has to be taken from the joystick port using the
power supply wire that is soldered to the freezer. Neither opening the Atari nor soldering
of any kind is required. Yet users with experience in soldering and with the appropriate
equipment have the option to add additional features.
The
TURBO FREEZER
consists of two parts, the freezer electronic in the black case
and an adapter board which establishes the connection to the PBI or ECI. The adapter
boards are available separately and hence provide a simple and cheap way to use a
TURBO FREEZER with Atari XL as well as with Atari XE computers.
Freezer
5V LED
Freezer
XE
XL
Atari
Cartridge
Figure 1.1: Atari XL and XE adapter boards
There is a small number of models from the XE series (mainly 65 XE) which do not
have an ECI port. These models only have a “Cartridge” port and have no “Expansion”